{"id":650,"date":"2024-04-21T17:00:45","date_gmt":"2024-04-21T17:00:45","guid":{"rendered":"https:\/\/testna.com.hr\/kontrolkem\/?p=650"},"modified":"2025-03-11T11:42:33","modified_gmt":"2025-03-11T11:42:33","slug":"boiler-water-treatment","status":"publish","type":"post","link":"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/","title":{"rendered":"Boiler Water Treatment"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"855\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg\" alt=\"\" class=\"wp-image-1517\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg 1280w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-768x513.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-large-font-size\">Why treat industrial boiler water?<\/h2>\n\n\n\n<h2 class=\"wp-block-heading has-large-font-size\">Scale <\/h2>\n\n\n\n<p>Scale formation is a significant issue in boiler systems, primarily caused by the precipitation of salts (calcium, magnesium, silica). This buildup can lead to several problems:<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0b50e75d alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-6d57e1b4\">\n<div class=\"wp-block-uagb-image uagb-block-81501216 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_1746908570-1024x683-1.jpg ,https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_1746908570-1024x683-1.jpg 780w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_1746908570-1024x683-1.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_1746908570-1024x683-1.jpg\" alt=\"\" class=\"uag-image-1414\" width=\"1024\" height=\"683\" title=\"Tube,Sheet,Plate,Of,Heat,Exchanger,Or,Boiler,Closeup,Texture\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-061f7015\">\n<ul class=\"wp-block-list\">\n<li><strong>Reduced Heat Transfer Efficiency:<\/strong>&nbsp;Scale acts as an insulating layer on heat transfer surfaces, making it harder for heat to be transferred from the combustion gases to the water. This inefficiency can cause the boiler to consume more energy, increasing operational costs.<\/li>\n\n\n\n<li><strong>Increased Pressure and Temperature:<\/strong>&nbsp;As scale accumulates, it can restrict water flow, leading to increased pressure and temperature within the boiler. This not only stresses the system but can also lead to equipment failures.<\/li>\n\n\n\n<li><strong>Frequent Maintenance and Downtime:<\/strong>&nbsp;The presence of scale often requires more frequent maintenance interventions, resulting in increased downtime and associated costs.<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-large-font-size\">Corrosion <\/h2>\n\n\n\n<p>Corrosion is another critical concern for boiler systems, occurring when metal components are exposed to water and oxygen. The consequences of corrosion include:<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-69be23b5 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-e31c6f57\">\n<div class=\"wp-block-uagb-image uagb-block-8bdea6d1 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_621546305-1024x768-1.jpg ,https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_621546305-1024x768-1.jpg 780w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_621546305-1024x768-1.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/shutterstock_621546305-1024x768-1.jpg\" alt=\"\" class=\"uag-image-1417\" width=\"1024\" height=\"768\" title=\"Corrosion,Product,In,The,Heat,Exchanger,,Corrosion,Scale,In,Industrial,\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-1a400ca6\">\n<ul class=\"wp-block-list\">\n<li><strong>Material Degradation:<\/strong>&nbsp;Corrosion leads to the disintegration of metal components, which can result in leaks or even failures if not addressed promptly. Pitting corrosion, in particular, creates localized weak points that can deepen over time.<\/li>\n\n\n\n<li><strong>Increased Repair Costs:<\/strong>&nbsp;Corroded components require replacement or repair, which can be costly and time-consuming. This not only affects the budget but also disrupts operations.<\/li>\n\n\n\n<li><strong>Reduced System Efficiency:<\/strong>&nbsp;As corrosion products accumulate, they can contribute to further scaling, creating a vicious cycle that diminishes overall efficiency.<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\"><strong>Sol<\/strong>utions<\/mark><\/h2>\n\n\n\n<p>To combat the issues of scale and corrosion in industrial boilers (low, medium and high pressure) , KontrolKem offers a range of chemical treatments and equipment solutions:<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Chemicals<\/mark><\/h2>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">      \n\t\t\t<div class=\"uagb-icon-wrapper uagb-block-605d013f      \"\n\t\t\tstyle=\"\" >\n\t\t\t\t\t\t\t\t\t<span class=\"uagb-svg-wrapper\" \n\t\t\t\t\t aria-label=\"glass-water-droplet\"\t\t\t\t\ttabindex=\"0\">\t\t\n\t\t\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 384 512\" role=\"graphics-symbol\" aria-hidden=\"false\" aria-label=\"\"><path d=\"M256 196C256 229.1 227.3 256 192 256C156.7 256 128 229.1 128 196C128 171.1 161.7 125.9 180.2 102.5C186.3 94.77 197.7 94.77 203.8 102.5C222.3 125.9 256 171.1 256 196V196zM352 0C360.9 0 369.4 3.692 375.4 10.19C381.5 16.69 384.6 25.42 383.9 34.28L355.1 437.7C352.1 479.6 317.3 512 275.3 512H108.7C66.72 512 31.89 479.6 28.9 437.7L.0813 34.28C-.5517 25.42 2.527 16.69 8.58 10.19C14.63 3.692 23.12 0 32 0L352 0zM96 304C116.1 314.1 139.9 314.1 160 304C180.1 293.9 203.9 293.9 224 304C244.1 314.1 267.9 314.1 288 304L300.1 297.5L317.6 64H66.37L83.05 297.5L96 304z\"><\/path><\/svg>\n\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Oxygen Scavengers:<\/strong>&nbsp;By removing dissolved oxygen from the water, these agents help prevent oxidative corrosion<em>.<\/em><\/li>\n\n\n\n<li><strong>Scale Inhibitors and Dispersants:<\/strong>&nbsp;Specially formulated chemicals prevent scale formation by modifying the crystallization process of minerals in the water and dispersing minerals preventing accumulation.<\/li>\n\n\n\n<li><strong>Corrosion Inhibitors:<\/strong>&nbsp;These chemicals protect metal surfaces from corrosive elements by forming a protective film that minimizes direct contact with harmful substances.<\/li>\n\n\n\n<li><strong>Neutralizing Amines:<\/strong> These volatile compounds are essential for controlling corrosion in condensate systems by neutralizing carbonic acid formed from dissolved carbon dioxide.<\/li>\n\n\n\n<li><strong>Antifoamers<\/strong>: Reduce the tendency of water to foam, when high in salt content, thus decreasing the need for blowdown and provides excellent energy savings.<\/li>\n\n\n\n<li><strong>Acidic cleaning chemicals: <\/strong> Used to dissolve and remove metal deposits and hard scale from industrial boilers, restoring heat transfer efficiency. Include corrosion inhibitors to minimize damage to metal surfaces during cleaning.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Equipment<\/mark> <\/h2>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">      \n\t\t\t<div class=\"uagb-icon-wrapper uagb-block-e12c27c7      \"\n\t\t\tstyle=\"\" >\n\t\t\t\t\t\t\t\t\t<span class=\"uagb-svg-wrapper\" \n\t\t\t\t\t aria-label=\"arrow-up-from-ground-water\"\t\t\t\t\ttabindex=\"0\">\t\t\n\t\t\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 576 512\" role=\"graphics-symbol\" aria-hidden=\"false\" aria-label=\"\"><path d=\"M256 319.1V109.3L230.6 134.6C218.1 147.1 197.9 147.1 185.4 134.6C172.9 122.1 172.9 101.9 185.4 89.37L265.4 9.372C277.9-3.124 298.1-3.124 310.6 9.372L390.6 89.37C403.1 101.9 403.1 122.1 390.6 134.6C378.1 147.1 357.9 147.1 345.4 134.6L320 109.3V319.1C320 337.7 305.7 352 288 352C270.3 352 256 337.7 256 319.1zM269.5 421.9C280.6 414 295.4 414 306.5 421.9C328.1 437.4 356.5 448 384 448C410.9 448 439.4 437.2 461.4 421.9L461.5 421.9C473.4 413.4 489.5 414.1 500.7 423.6C515.1 435.5 533.2 444.6 551.3 448.8C568.5 452.8 579.2 470.1 575.2 487.3C571.2 504.5 553.1 515.2 536.7 511.2C512.2 505.4 491.9 494.6 478.5 486.2C449.5 501.7 417 512 384 512C352.1 512 323.4 502.1 303.6 493.1C297.7 490.5 292.5 487.8 288 485.4C283.5 487.8 278.3 490.5 272.4 493.1C252.6 502.1 223.9 512 192 512C158.1 512 126.5 501.7 97.5 486.2C84.13 494.6 63.79 505.4 39.27 511.2C22.06 515.2 4.854 504.5 .8429 487.3C-3.168 470.1 7.533 452.8 24.74 448.8C42.84 444.6 60.96 435.5 75.31 423.6C86.46 414.1 102.6 413.4 114.5 421.9L114.6 421.9C136.7 437.2 165.1 448 192 448C219.5 448 247 437.4 269.5 421.9H269.5zM192 416.5C172.1 416.4 150.8 408.5 132.9 396.1C109.1 379.4 77.01 380.8 54.78 399.5C44.18 408.3 30.59 415.1 17.49 418.1C11.19 419.6 5.326 421.9 0 425V239.1C0 213.5 21.49 191.1 48 191.1H192V416.5zM576 239.1V424.1C570.7 421.9 564.8 419.6 558.5 418.1C545.4 415.1 531.8 408.3 521.2 399.5C499 380.8 466.9 379.4 443.2 396.1C425.2 408.5 403 416.5 384 416.5L384 191.1H528C554.5 191.1 576 213.5 576 239.1L576 239.1z\"><\/path><\/svg>\n\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Water Filtration Systems (sand, mechanical, special media):<\/strong>&nbsp;Effective filtration removes impurities that contribute to scaling and corrosion.<\/li>\n\n\n\n<li><strong>Micro\/Ultra\/Nano Filtration:<\/strong> These advanced membrane filtration processes utilize semipermeable membranes with varying pore sizes to separate particles and solutes from liquids<\/li>\n\n\n\n<li><strong>Water Softeners:<\/strong>&nbsp;These systems reduce hardness in feedwater, significantly minimizing scale buildup.<\/li>\n\n\n\n<li><strong>Reverse Osmosis (RO) :<\/strong>&nbsp;RO systems effectively remove dissolved solids and contaminants from water, reducing both scaling and corrosion risks.<\/li>\n\n\n\n<li><strong>Electrodeionization (EDI) Systems:<\/strong>&nbsp;EDI provides high-purity water by removing ions from feedwater, further protecting boiler components.<\/li>\n\n\n\n<li><strong>Mixed Bed :<\/strong> Use a combination of cation and anion exchange resins to achieve extremely low conductivity water.<\/li>\n\n\n\n<li><strong>Chemical Dosing Pumps:<\/strong> Accurately inject treatment chemicals  to maintain optimal boiler water conditions.<\/li>\n\n\n\n<li><strong>Automated Blowdown Systems:<\/strong> Control and manage boiler blowdown based on real-time conductivity measurements, optimizing water usage and reducing energy loss.<\/li>\n\n\n\n<li><strong>Dissolved Oxygen (DO) Sensors:<\/strong> Continuous monitoring of oxygen levels helps detect and prevent corrosion risks.<\/li>\n<\/ul>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-650_807b97-7d .kt-block-spacer{height:25px;}.wp-block-kadence-spacer.kt-block-spacer-650_807b97-7d .kt-divider{border-top-width:1px;height:1px;border-top-color:var(--global-palette9, #ffffff);width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-650_807b97-7d\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-theme-palette-2-color has-alpha-channel-opacity has-theme-palette-2-background-color has-background\"\/>\n\n\n\n<div data-aos= \"flip-left\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-e0623bdf alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-aef00892\">\n<p>Optimize your industrial process with our expert water treatment solutions, designed to improve efficiency and protect the environment. Contact us today to schedule a meeting and discover how we can help you achieve your goals!<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-b66daeb4\"><style>.wp-block-kadence-advancedbtn.kb-btns650_bd09fe-79{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns650_bd09fe-79 .kt-button{font-weight:normal;font-style:normal;}.kt-btns650_bd09fe-79 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns650_bd09fe-79 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns650_bd09fe-79 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns650_bd09fe-79 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns650_bd09fe-79 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns650_bd09fe-79 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns650_bd09fe-79 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns650_bd09fe-79\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn650_54c771-39.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn650_54c771-39.kb-button{border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-right-radius:20px;border-bottom-left-radius:20px;}.wp-block-kadence-advancedbtn .kb-btn650_54c771-39.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn650_54c771-39.kb-button:focus{color:var(--global-palette2, #2B6CB0);background:var(--global-palette8, #F7FAFC);}@media all and (max-width: 1024px){.kb-btn650_54c771-39.kb-button .kb-svg-icon-wrap{display:block;}}<\/style><a class=\"kb-button kt-button button kb-btn650_54c771-39 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/testna.com.hr\/kontrolkem\/contact-form\/\"><span class=\"kt-btn-inner-text\">Contact Us<\/span><\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n\t\t\t<div class=\"wp-block-uagb-post-grid uagb-post-grid  uagb-post__image-position-top uagb-post__image-enabled uagb-block-a86bfb45     uagb-post__items uagb-post__columns-3 is-grid uagb-post__columns-tablet-2 uagb-post__columns-mobile-1 uagb-post__equal-height\" data-total=\"1\" style=\"\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/reverse-osmosis-membrane-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/water-treatment-equipment-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/water-treatment-equipment-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/water-treatment-equipment-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/water-treatment-equipment-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/water-treatment-equipment.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/reverse-osmosis-membrane-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Pretreatment<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/reverse-osmosis-membrane-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/waste-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/waste-water-treatment-kontrolkem-1-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/waste-water-treatment-kontrolkem-1-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/waste-water-treatment-kontrolkem-1-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/waste-water-treatment-kontrolkem-1-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/waste-water-treatment-kontrolkem-1.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/waste-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Waste Water Treatment<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/waste-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/cooling-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/cooling-water-treatment-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/cooling-water-treatment-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/cooling-water-treatment-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/cooling-water-treatment-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/cooling-water-treatment-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/cooling-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Cooling Water Treatment<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/cooling-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Boiler Water Treatment<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>Why treat industrial boiler water? Scale Scale formation is a significant issue in boiler systems, primarily caused by the precipitation of salts (calcium, magnesium, silica). This buildup can lead to several problems: Corrosion Corrosion is another critical concern for boiler systems, occurring when metal components are exposed to water and oxygen. The consequences of corrosion&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1517,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[22],"tags":[],"class_list":["post-650","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications"],"uagb_featured_image_src":{"full":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg",1280,855,false],"thumbnail":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-150x150.jpg",150,150,true],"medium":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-300x200.jpg",300,200,true],"medium_large":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-768x513.jpg",768,513,true],"large":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-1024x684.jpg",1024,684,true],"1536x1536":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg",1280,855,false],"2048x2048":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg",1280,855,false]},"uagb_author_info":{"display_name":"Urednik1","author_link":"https:\/\/testna.com.hr\/kontrolkem\/author\/urednik1\/"},"uagb_comment_info":0,"uagb_excerpt":"Why treat industrial boiler water? Scale Scale formation is a significant issue in boiler systems, primarily caused by the precipitation of salts (calcium, magnesium, silica). This buildup can lead to several problems: Corrosion Corrosion is another critical concern for boiler systems, occurring when metal components are exposed to water and oxygen. The consequences of corrosion...","_links":{"self":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts\/650","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/comments?post=650"}],"version-history":[{"count":36,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts\/650\/revisions"}],"predecessor-version":[{"id":1750,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts\/650\/revisions\/1750"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/media\/1517"}],"wp:attachment":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/media?parent=650"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/categories?post=650"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/tags?post=650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}