{"id":711,"date":"2024-04-21T17:52:31","date_gmt":"2024-04-21T17:52:31","guid":{"rendered":"https:\/\/testna.com.hr\/kontrolkem\/?p=711"},"modified":"2025-03-11T11:47:31","modified_gmt":"2025-03-11T11:47:31","slug":"power-plants","status":"publish","type":"post","link":"https:\/\/testna.com.hr\/kontrolkem\/power-plants\/","title":{"rendered":"Power plants"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-5e80c342 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg ,https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg 780w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg\" alt=\"\" class=\"uag-image-995\" width=\"1280\" height=\"855\" title=\"power plants kontrolkem\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"font-size:16px\">Water treatment in power plants is essential for ensuring <strong><em>operational efficiency<\/em><\/strong>, safety, and compliance with environmental regulations. <em><strong>High-quality water<\/strong><\/em> is crucial for steam generation, cooling systems, and various auxiliary processes. Treatment removes impurities that can cause corrosion, scaling, and fouling, which may impair equipment performance and <em><strong>increase maintenance costs<\/strong><\/em>.<\/p>\n\n\n\n<p style=\"font-size:16px\">Given the <strong><em>high pressures and temperatures<\/em><\/strong> in these systems, even minor contaminants can lead to significant operational challenges. Power plants also face stringent regulations regarding water usage and discharge, requiring advanced treatment techniques to meet environmental standards. Technologies like <strong><em>reverse osmosis<\/em><\/strong>, <strong><em>ion exchange<\/em><\/strong>, and <strong><em>advanced filtration<\/em><\/strong> are commonly employed to achieve the necessary water quality. Ongoing <strong><em>monitoring systems<\/em><\/strong> ensure consistent water quality throughout plant operations. Effective water treatment is vital not only for operational efficiency but also for promoting ecological sustainability.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-theme-palette-2-color has-alpha-channel-opacity has-theme-palette-2-background-color has-background\"\/>\n\n\n\n<div data-aos= \"flip-left\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-d5d50f70 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-869c9ab4\">\n<div class=\"wp-block-uagb-image uagb-block-fee59a93 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/cooling-water-treatment\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/cooling-water-treatment-kontrolkem-1024x684-1.jpg ,https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/cooling-water-treatment-kontrolkem-1024x684-1.jpg 780w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/cooling-water-treatment-kontrolkem-1024x684-1.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/cooling-water-treatment-kontrolkem-1024x684-1.jpg\" alt=\"Find out more\" class=\"uag-image-1445\" width=\"1024\" height=\"684\" title=\"Find out more\" loading=\"lazy\" role=\"img\"\/><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-9fe5df45\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-6c35e0c1\"><h2 class=\"uagb-heading-text\"><a href=\"https:\/\/testna.com.hr\/kontrolkem\/cooling-water-treatment\/\">Cooling Water Treatment Solutions<\/a><\/h2><\/div>\n\n\n\n<p>Discover how KontrolKem&#8217;s innovative cooling water treatment solutions can enhance the efficiency and longevity of your industrial cooling systems.<br> <br><a href=\"https:\/\/testna.com.hr\/kontrolkem\/cooling-water-treatment\/\">&gt;&gt; Find out more<\/a><\/p>\n<\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div data-aos= \"flip-left\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-a564bd96 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-7da20e67\">\n<div class=\"wp-block-uagb-image uagb-block-9e8ef1c4 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/\" target=\"\" rel=\"noopener\"><img decoding=\"async\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-1024x684.jpg ,https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg 780w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/boiler-water-treatment-kontrolkem-1024x684.jpg\" alt=\"\" class=\"uag-image-1473\" width=\"1024\" height=\"684\" title=\"boiler-water-treatment-kontrolkem\" loading=\"lazy\" role=\"img\"\/><\/a><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-3d9e25b2\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-3a6bc492\"><h2 class=\"uagb-heading-text\"><a href=\"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/\">Boiler Water Treatment<\/a><\/h2><\/div>\n\n\n\n<p>Learn how KontrolKem&#8217;s comprehensive boiler water treatment solutions, including advanced chemicals and equipment, prevent scale formation, corrosion, and other issues.<br> <br><a href=\"https:\/\/testna.com.hr\/kontrolkem\/boiler-water-treatment\/\">&gt;&gt; Find out more<\/a><\/p>\n<\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-uagb-advanced-heading uagb-block-2c7667e8\"><h2 class=\"uagb-heading-text\"><strong>High pressure boiler water and steam turbines challenges<\/strong><\/h2><\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\"><strong>Scaling and Deposition:<\/strong> Dissolved minerals such as <strong>calcium<\/strong>, <strong>magnesium<\/strong>, and <strong>silica <\/strong>cause scale deposits on boiler tubes, reducing <strong>heat transfer efficiency<\/strong><em> <\/em>and increasing <strong>energy consumption<\/strong>.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong>Corrosion:<\/strong> Dissolved gases like <strong>oxygen <\/strong>and <strong>carbon dioxide<\/strong> in feedwater lead to corrosion of boiler and steam systems, resulting in damage and reduced equipment lifespan.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong>Carryover and Foaming:<\/strong> Impurities, along with foam caused by high dissolved solids, lead to carryover in steam, causing deposits in turbines and other equipment.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong>Silica and Sodium Contamination:<\/strong> High levels of <strong>silica <\/strong>and <em><strong>sodium<\/strong> <\/em>in feedwater contribute to deposition on turbine blades and other steam system components.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong>Iron and Copper Oxides:<\/strong> Corrosion of feedwater and condensate return systems introduces <strong>iron <\/strong>and <strong>copper oxides<\/strong>, which can deposit in boilers and steam lines.<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\" style=\"font-size:20px\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Treatment Solutions<\/mark><\/strong><\/h2>\n<\/div><\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">      \n\t\t\t<div class=\"uagb-icon-wrapper uagb-block-263ca48d      \"\n\t\t\tstyle=\"\" >\n\t\t\t\t\t\t\t\t\t<span class=\"uagb-svg-wrapper\" \n\t\t\t\t\t aria-label=\"glass-water-droplet\"\t\t\t\t\ttabindex=\"0\">\t\t\n\t\t\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 384 512\" role=\"graphics-symbol\" aria-hidden=\"false\" aria-label=\"\"><path d=\"M256 196C256 229.1 227.3 256 192 256C156.7 256 128 229.1 128 196C128 171.1 161.7 125.9 180.2 102.5C186.3 94.77 197.7 94.77 203.8 102.5C222.3 125.9 256 171.1 256 196V196zM352 0C360.9 0 369.4 3.692 375.4 10.19C381.5 16.69 384.6 25.42 383.9 34.28L355.1 437.7C352.1 479.6 317.3 512 275.3 512H108.7C66.72 512 31.89 479.6 28.9 437.7L.0813 34.28C-.5517 25.42 2.527 16.69 8.58 10.19C14.63 3.692 23.12 0 32 0L352 0zM96 304C116.1 314.1 139.9 314.1 160 304C180.1 293.9 203.9 293.9 224 304C244.1 314.1 267.9 314.1 288 304L300.1 297.5L317.6 64H66.37L83.05 297.5L96 304z\"><\/path><\/svg>\n\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\n\n<ul class=\"wp-block-list\">\n<li><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\"><strong>Oxygen Scavengers:<\/strong> <\/mark>Removes dissolved oxygen using chemicals such as hydrazine, sulfite, or their alternatives.<\/li>\n\n\n\n<li><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Corrosion Inhibition:<\/mark><\/strong> Protect metal surfaces from oxidation and corrosion and ensures pH control and minimizes corrosion with use of amines, phosphates, or specialized filming inhibitors.<\/li>\n\n\n\n<li><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Anti-Foam Agents:<\/mark> <\/strong>Add antifoaming chemicals to the boiler water treatment program Prevent foaming that leads to steam impurities and carryover and increase cycles of concentrations and reducing blowdown and energy loss. <\/li>\n<\/ul>\n<\/div>\n<\/blockquote>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">      \n\t\t\t<div class=\"uagb-icon-wrapper uagb-block-fd7c4550      \"\n\t\t\tstyle=\"\" >\n\t\t\t\t\t\t\t\t\t<span class=\"uagb-svg-wrapper\" \n\t\t\t\t\t aria-label=\"arrow-up-from-ground-water\"\t\t\t\t\ttabindex=\"0\">\t\t\n\t\t\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 576 512\" role=\"graphics-symbol\" aria-hidden=\"false\" aria-label=\"\"><path d=\"M256 319.1V109.3L230.6 134.6C218.1 147.1 197.9 147.1 185.4 134.6C172.9 122.1 172.9 101.9 185.4 89.37L265.4 9.372C277.9-3.124 298.1-3.124 310.6 9.372L390.6 89.37C403.1 101.9 403.1 122.1 390.6 134.6C378.1 147.1 357.9 147.1 345.4 134.6L320 109.3V319.1C320 337.7 305.7 352 288 352C270.3 352 256 337.7 256 319.1zM269.5 421.9C280.6 414 295.4 414 306.5 421.9C328.1 437.4 356.5 448 384 448C410.9 448 439.4 437.2 461.4 421.9L461.5 421.9C473.4 413.4 489.5 414.1 500.7 423.6C515.1 435.5 533.2 444.6 551.3 448.8C568.5 452.8 579.2 470.1 575.2 487.3C571.2 504.5 553.1 515.2 536.7 511.2C512.2 505.4 491.9 494.6 478.5 486.2C449.5 501.7 417 512 384 512C352.1 512 323.4 502.1 303.6 493.1C297.7 490.5 292.5 487.8 288 485.4C283.5 487.8 278.3 490.5 272.4 493.1C252.6 502.1 223.9 512 192 512C158.1 512 126.5 501.7 97.5 486.2C84.13 494.6 63.79 505.4 39.27 511.2C22.06 515.2 4.854 504.5 .8429 487.3C-3.168 470.1 7.533 452.8 24.74 448.8C42.84 444.6 60.96 435.5 75.31 423.6C86.46 414.1 102.6 413.4 114.5 421.9L114.6 421.9C136.7 437.2 165.1 448 192 448C219.5 448 247 437.4 269.5 421.9H269.5zM192 416.5C172.1 416.4 150.8 408.5 132.9 396.1C109.1 379.4 77.01 380.8 54.78 399.5C44.18 408.3 30.59 415.1 17.49 418.1C11.19 419.6 5.326 421.9 0 425V239.1C0 213.5 21.49 191.1 48 191.1H192V416.5zM576 239.1V424.1C570.7 421.9 564.8 419.6 558.5 418.1C545.4 415.1 531.8 408.3 521.2 399.5C499 380.8 466.9 379.4 443.2 396.1C425.2 408.5 403 416.5 384 416.5L384 191.1H528C554.5 191.1 576 213.5 576 239.1L576 239.1z\"><\/path><\/svg>\n\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\n\n<ul class=\"wp-block-list\">\n<li><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Reverse Osmosis:<\/mark><\/strong> Achieve ultra-pure water by removing dissolved solids by using reverse osmosis membranes for feedwater pre-treatment.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">CEDI (Continuous Electrodeionization) and Mixed Bed Polishing:<\/mark><\/strong> Use CEDI and mixed-bed resin systems for final polishing to achieve extremely low levels of ionic contamination to produce ultrapure water for high-pressure boilers.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Condensate Polishing:<\/mark><\/strong> By employing an ion exchange resin or filtration systems to maintain high condensate purity by removing dissolved impurities such as silica and metals (iron, copper).<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Conductivity\/ Silica\/ Sodium Monitoring:<\/mark><\/strong> Use online conductivity meters to detect contamination and trigger corrective actions by continuously monitoring condensate and feedwater purity to prevent turbine blade deposits.<\/li>\n\n\n\n<li style=\"font-size:16px\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Blowdown Systems:<\/mark><\/strong> Automated blowdown controls optimize water removal while maintaining boiler efficiency to minimize dissolved solids and prevent scale and carryover.<\/li>\n<\/ul>\n<\/div>\n<\/blockquote>\n<\/div><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-theme-palette-2-color has-alpha-channel-opacity has-theme-palette-2-background-color has-background\"\/>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-711_deb3af-f8 .kt-block-spacer{height:25px;}.wp-block-kadence-spacer.kt-block-spacer-711_deb3af-f8 .kt-divider{border-top-width:1px;height:1px;border-top-color:var(--global-palette9, #ffffff);width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-711_deb3af-f8\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<p>Effective high pressure boiler water treatment solutions are crucial for maintaining operational efficiency and safety in steam turbine operations. KontrolKem offers specialized services to address challenges such as scaling, corrosion, and water quality issues. If you\u2019re facing any of these challenges, <strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">don\u2019t hesitate to contact us for expert guidance and tailored solutions.<\/mark><\/strong> <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-theme-palette-2-color has-alpha-channel-opacity has-theme-palette-2-background-color has-background\"\/>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-711_3a0361-ef .kt-block-spacer{height:25px;}.wp-block-kadence-spacer.kt-block-spacer-711_3a0361-ef .kt-divider{border-top-width:1px;height:1px;border-top-color:var(--global-palette9, #ffffff);width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-711_3a0361-ef\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<div data-aos= \"flip-left\" data-aos-duration=\"400\" data-aos-delay=\"0\" data-aos-easing=\"ease\" data-aos-once=\"true\" class=\"wp-block-uagb-container uagb-block-e0623bdf alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-aef00892\">\n<p>Optimize your industrial process with our expert water treatment solutions, designed to improve efficiency and protect the environment. Contact us today to schedule a meeting and discover how we can help you achieve your goals!<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-b66daeb4\"><style>.wp-block-kadence-advancedbtn.kb-btns711_3c5ecd-c3{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns711_3c5ecd-c3 .kt-button{font-weight:normal;font-style:normal;}.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns711_3c5ecd-c3 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns711_3c5ecd-c3\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn711_0424e4-72.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn711_0424e4-72.kb-button{border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-right-radius:20px;border-bottom-left-radius:20px;}.wp-block-kadence-advancedbtn .kb-btn711_0424e4-72.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn711_0424e4-72.kb-button:focus{color:var(--global-palette2, #2B6CB0);background:var(--global-palette8, #F7FAFC);}@media all and (max-width: 1024px){.kb-btn711_0424e4-72.kb-button .kb-svg-icon-wrap{display:block;}}<\/style><a class=\"kb-button kt-button button kb-btn711_0424e4-72 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/testna.com.hr\/kontrolkem\/contact-form\/\"><span class=\"kt-btn-inner-text\">Contact Us<\/span><\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-711_4d88fa-57 .kt-block-spacer{height:25px;}.wp-block-kadence-spacer.kt-block-spacer-711_4d88fa-57 .kt-divider{border-top-width:1px;height:1px;border-top-color:var(--global-palette9, #ffffff);width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-711_4d88fa-57\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n\t\t\t<div class=\"wp-block-uagb-post-grid uagb-post-grid  uagb-post__image-position-top uagb-post__image-enabled uagb-block-a88e2420     uagb-post__items uagb-post__columns-3 is-grid uagb-post__columns-tablet-2 uagb-post__columns-mobile-1 uagb-post__equal-height\" data-total=\"1\" style=\"\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/electroplating-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-scaled-1-1024x683.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-scaled-1-1024x683.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-scaled-1-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-scaled-1-768x512.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-scaled-1-1536x1024.jpg 1536w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-scaled-1-2048x1366.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/electroplating-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Electroplating industry<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Water treatment in the electroplating industry is a highly specialized process, addressing the unique contaminants&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/electroplating-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/electronics-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-2048x1365-2-1024x683.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-2048x1365-2-1024x683.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-2048x1365-2-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-2048x1365-2-768x512.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-2048x1365-2-1536x1024.jpg 1536w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/shutterstock_2221174589-2048x1365-2.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/electronics-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Electronics industry<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Water treatment in the electronics industry is critical due to the strict purity requirements for&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/electronics-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/waterworks\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/Waterworks-kontrolkem-1-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/Waterworks-kontrolkem-1-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/Waterworks-kontrolkem-1-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/Waterworks-kontrolkem-1-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/Waterworks-kontrolkem-1.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/waterworks\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Geothermal<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>The geothermal industry plays a crucial role in the transition to renewable energy, utilizing the&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/waterworks\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/paper\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/paper-industries-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/paper-industries-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/paper-industries-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/paper-industries-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/paper-industries-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/paper\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Paper<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Water treatment plays a vital role in the paper industry, where large volumes of water&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/paper\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/automotive\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/automotive-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/automotive-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/automotive-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/automotive-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/automotive-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/automotive\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Automotive<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>In the automotive industry, paint application is a crucial process that significantly influences the final&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/automotive\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/pharmaceutical-industries\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/pharmaceutical-industries-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/pharmaceutical-industries-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/pharmaceutical-industries-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/pharmaceutical-industries-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/pharmaceutical-industries-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/pharmaceutical-industries\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Pharmaceutical industries<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Water treatment is a vital aspect of the pharmaceutical industry, ensuring the purity and safety&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/pharmaceutical-industries\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/oil-refineries\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/oil-refinery-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/oil-refinery-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/oil-refinery-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/oil-refinery-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/10\/oil-refinery-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/oil-refineries\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Petrochemical<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Water treatment in petrochemical facilities, including fertilizer plants and oil refineries, is essential for ensuring&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/oil-refineries\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/power-plants\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-1024x684.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-1024x684.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-768x513.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/power-plants\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Power plants<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Water treatment in power plants is essential for ensuring operational efficiency, safety, and compliance with&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/power-plants\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<article class=\"uagb-post__inner-wrap\">\t\t\t\t\t\t\t\t<div class='uagb-post__image'>\n\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/steel-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\" class='uagb-image-ratio-inherit'><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"682\" src=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/kontrolkem-steel-industry-1-1024x682.jpg\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/kontrolkem-steel-industry-1-1024x682.jpg 1024w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/kontrolkem-steel-industry-1-300x200.jpg 300w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/kontrolkem-steel-industry-1-768x511.jpg 768w, https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/kontrolkem-steel-industry-1.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<h4 class=\"uagb-post__title uagb-post__text\">\n\t\t\t\t<a href=\"https:\/\/testna.com.hr\/kontrolkem\/steel-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">Metalcasting<\/a>\n\t\t\t<\/h4>\n\t\t\t\t\t\t<div class='uagb-post__text uagb-post-grid-byline'>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class='uagb-post__text uagb-post__excerpt'>\n\t\t\t\t\t<p>Effective water treatment is essential in the metal casting industry to ensure optimal cooling and&#8230;\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"uagb-post__text uagb-post__cta wp-block-button\">\n\t\t\t\t<a class=\"wp-block-button__link uagb-text-link\" style=\"\" href=\"https:\/\/testna.com.hr\/kontrolkem\/steel-industry\/\" target=\"_self\" rel=\"bookmark noopener noreferrer\">More&#8230;<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t\t\t<\/article>\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>Water treatment in power plants is essential for ensuring operational efficiency, safety, and compliance with environmental regulations. High-quality water is crucial for steam generation, cooling systems, and various auxiliary processes. Treatment removes impurities that can cause corrosion, scaling, and fouling, which may impair equipment performance and increase maintenance costs. Given the high pressures and temperatures&#8230;<\/p>\n","protected":false},"author":1,"featured_media":995,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[30],"tags":[],"class_list":["post-711","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industries"],"uagb_featured_image_src":{"full":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg",1280,855,false],"thumbnail":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-150x150.jpg",150,150,true],"medium":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-300x200.jpg",300,200,true],"medium_large":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-768x513.jpg",768,513,true],"large":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem-1024x684.jpg",1024,684,true],"1536x1536":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg",1280,855,false],"2048x2048":["https:\/\/testna.com.hr\/kontrolkem\/wp-content\/uploads\/2024\/04\/power-plants-kontrolkem.jpg",1280,855,false]},"uagb_author_info":{"display_name":"Urednik1","author_link":"https:\/\/testna.com.hr\/kontrolkem\/author\/urednik1\/"},"uagb_comment_info":0,"uagb_excerpt":"Water treatment in power plants is essential for ensuring operational efficiency, safety, and compliance with environmental regulations. High-quality water is crucial for steam generation, cooling systems, and various auxiliary processes. Treatment removes impurities that can cause corrosion, scaling, and fouling, which may impair equipment performance and increase maintenance costs. Given the high pressures and temperatures...","_links":{"self":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts\/711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/comments?post=711"}],"version-history":[{"count":26,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts\/711\/revisions"}],"predecessor-version":[{"id":1759,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/posts\/711\/revisions\/1759"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/media\/995"}],"wp:attachment":[{"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/media?parent=711"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/categories?post=711"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/testna.com.hr\/kontrolkem\/wp-json\/wp\/v2\/tags?post=711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}